عنوان عکس اسلایدر عنوان عکس اسلایدر عنوان عکس اسلایدر
نویسنده:
تاریخ: سه شنبه 23 خرداد 1396
بازدید: 97

More and more popular for marathon racing in China recent years. As the quantity of runners increasing rapidly, traditional timing system like manual timing, infrared timing could not support such large number of runners at the same time. UHF RFID technology is now the number one technology used for mass participation running events.

Firstly, the UHF reader must support the multiple reading and long distance reading, Clou's new fixed UHF RFID reader CL7206C8 perfectly fit for the field. CL7206C8 support max 20m reading, and 200pcs/second rate.

8 port Long Range UHF RFID Reader

Working with the UHF reader, another important part of RFID timing system is RFID mat antennas. The antennas should be well performance for anti-interference and support fast detecting. Clou's 6dBi CL7205F antennas, which installed on the floor and IP66 rugged, have worked for many marathon racing around the world.

نویسنده:
تاریخ: دوشنبه 22 خرداد 1396
بازدید: 88

Electronic Toll Collection (ETC) aims to eliminate the delay on toll roads by collecting tolls electronically. ETC system rely on some roadside equipment at frontend including automatic vehicle identification (AVI) devices, automatic vehicle classification (AVC) apparatus, and violation enforcement cameras.

System for AVI have been around for many years since the 1960s. Not long ago, active or semi-passive RFID AVI system gained much attention in ETC in different countries, e.g. 5.8GHz in Europe and Japan, and 915MHz in the US. Its maintenance costs is high, and has limited lifetime as it is battery operated. Moreover, active or semi-passive RFID tag is expensive, relatively large, and the communication protocol is not standardized.

Since 2012, there is growing interest in ISO 18000-6C passive UHF RFID technology in tolling system in the US. Some countries and locations have also started to switch to use passive UHF RIFD for tolling in recent years such as Taiwan, Vietnam, India, and North America, etc. The advantages of using passive UHF RFID technology (ISO 18000-6C) in AVI application is its inherent low maintenance cost. Moreover, the technology of passive UHF RFID is mature enough to provide the required read range and reliability in AVI applications. In addition, passive UHF RFID tag is relative small and low in profile, it has no battery for operation, it communicates with standard protocol of ISO 18000-6C EPC Class 1 Gen2 worldwide. Therefore, passive UHF RFID technology is a cost effective way for AVI, and definitely becoming parts of the global standard for electronic toll collection.

 

نویسنده:
تاریخ: پنجشنبه 18 خرداد 1396
بازدید: 94

Off-grid PV power generation system mainly by the PV modules, brackets, controllers, inverters, batteries and power distribution system components. System electrical design, the main consideration components, solar controller, solar inverter , battery selection and calculation. Before the design, the preparatory work need some time. You need to understand the user installation site of the climatic conditions, load type and power; day and night electricity consumption. Of course, need to know the user's budget and economic situation. In off grid PV power generation system, electricity is depend on weather. However,weather changed frequently.


After know the above situation, you can start to do the design.


Three principles of off - grid PV power generation system design


1.According to the user's load type and power to determine the power of off-grid inverter, home load is generally divided into inductive and resistive load, washing machine, air conditioning, refrigerator, water pump, range hood with motor load is emotional load , The motor starting power is 5-7 times the rated power, in the calculation of the inverter power, the load should take into account the starting power. The output power of the inverter is greater than the power of the load. For the monitoring station, communication stations and other demanding occasions, the output power is the sum of the load power. However, for the general poor households, taking into account all the load can not be opened at the same time, in order to save costs, you can multiply the sum of the load power of 0.7-0.9 coefficient.


2.According to the user's daily electricity consumption to confirm the component power. The design principle of the component is to meet the daily demand for daily electricity consumption under average weather conditions, that is to say, the annual electricity generation of solar modules should be equal to the annual electricity consumption of the load. Because the weather conditions are below and above the average, the solar cell components are designed to meet the needs of the worst season of light, that is, in the worst season, the battery can be basically filled with electricity every day. But in some areas, the worst season of the light is much lower than the annual average, if the worst case design of the solar cell module power, then the other time in the year when the power generation will be far more than the actual needs , Causing waste. At this time can only consider the appropriate increase in the design capacity of the battery to increase the energy storage, so that the battery is in a shallow discharge state, to make up for the light of the worst season power generation capacity of the damage caused by storage turbidity. The power generation capacity of the module can not be completely converted into electricity, but also consider the efficiency of the controller and the loss of the machine and the loss of the battery, the solar controller has two types of PWM and MPPT, PWM controller efficiency of about 85%, the input voltage range Relatively narrow, but the price is relatively low, MPPT controller efficiency of about 95%, the price is relatively high. Battery charge and discharge process, there will be 10-15% loss.


Off-grid system available power = total power of components * average number of solar power generation * controller efficiency * battery efficiency.


3.according to the user at night or expect standby time to determine the battery capacity. The task of the battery is to reduce the amount of solar radiation, the system to ensure the normal load of electricity. For important load, to be able to within a few days to ensure the normal work of the system, to consider the number of consecutive rainy days. For the general load such as solar lights can be based on experience or need to choose within 2 to 3 days. Important loads such as communication, navigation, hospital treatment, etc. in 3 to 7 days selected. Also consider the installation location of the photovoltaic power generation system, if in remote areas, the battery capacity to design a larger, because the maintenance staff to reach the scene will take a long time. In practice, some mobile communication base stations are very convenient because they are far away from the mountain. In addition to the configuration of the normal battery pack, a set of spare battery packs is provided. For the poor families, the main consideration is the price. Rainy days, the sun is good when used. When the sun is not good use, no sun is not used. Select the load, try to use energy-saving equipment, such as LED lights, inverter air conditioner. The design of the battery mainly includes the design of the battery capacity and the design of the combination of the battery string and parallel. In the photovoltaic power generation system, most of the use of lead-acid batteries, taking into account the battery life, generally take the depth of 0.5-0.7 between the discharge.


Battery design capacity = (load daily electricity consumption * continuous rain days) / battery discharge depth.


JNGE series of solar power generation system are sets of solar panel, battery, charge controller, inverter,and so on. We can provide you with off grid solar power system home, DC to AC pure sine wave inverter and low frequency pure sine wave inverter, etc.


برچسب ها : ,,,
نویسنده:
تاریخ: پنجشنبه 18 خرداد 1396
بازدید: 84

Business process re-engineering is gaining popularity nowadays due to the budgets constraints imposed by the economic crisis. It’s easy to notice an increasing usage of Radio Frequency Identification (RFID) and near field communication (NFC) in several domains. For example, reported the use of RFID technology in museums and galleries for tracking artworks and other expensive pieces while moved from one art gallery to another. More than 3000 universities in China have installed RFID tag readers, for student identification cards, and contactless library applications. Hospitals also started using UHF RFID tags to track and manage assets, particularly expensive or critical items of equipment.

Take the case of warehousing management system(WMS) for discussion, structure the activities into three main processes.

1. Consumable items management:

For consumable items like clothes, shoes; they need to record all the details (person equipment, date of check in and date of check-out) while they are delivering items within warehouse. The tracking would be challenged owing to big quantity and dense. Multi-channels UHF fixed RFID reader could make it work, with max 8 pieces of antennas, greatly improve accuracy of tracking and counting.

8 port Long Range UHF RFID Reader

2. Special items and package management:
Some other items would be special for RFID reader, such as bottle of water, fruit, metal household appliances etc. Since the metal material and water have mad impact of RFID signal. In this cases, we use special anti-metal or anti-collision RFID tags to reduce adverse effects.

3. Warehouse inventory:

Once in a month, the warehousing department has to conduct an inventory of all the items in the stock by staff manually. UHF RFID handheld terminal could solve the problems well, with RFID tags/labels on every items. By high reading rate(400pcs/s) and long distance reading(10m), greatly increase the efficiency and save cost of labor.

نویسنده:
تاریخ: سه شنبه 16 خرداد 1396
بازدید: 89

UHF RFID readers can be divided into fixed RFID readers and handheld readers. Handheld readers achieved a large number of applications for its portable, and easy to use in shift data collection.

It is difficult to design handheld UHF RFID reader, because it covers embedded computer application, microwave and antenna, radio frequency electronic circuit, wireless communications and signal processing, low-power control and many other technical fields.

Based on the ARM9 chip S3C2440 of Samsung Corporation (SAMSUN), the UHF reader ASIC AS3990 of Austria Microsystems Corporation (AG) and a nine-channel programmable DC-DC power manager with battery charger SMB122 of Summit Microelectronics Corporation, a low power handheld UHF RFID reader is designed, and its lowpower control program is analyzed and designed in detail.

When the system is in working state, power is consumed mainly by RF transmitter circuit. MATLAB simulation and experimental measurements indicated that UHF RFID read range is determined by several combined factors, such as reader's transmitting power, VCO's noise strength, circulator's isolation, antenna's gain and so on. When the transmitting power reaching a certain value, continue increasing the transmitting power does not lead to a further increase of read range, the read range is decided by backward link constraint at this time.

UHF RFID Handheld Reader

نویسنده:
تاریخ: دوشنبه 15 خرداد 1396
بازدید: 116

.

PV controllers can be divided into five types: parallel, tandem, pulse width modulation, intelligent and maximum power tracking.


Parallel controller: When the battery is full, the use of electronic components to the output of the PV array shunt to the internal parallel resistor or power module up, and then consumed in the form of heat. Because this way consumes heat, it is generally used for small, low power systems, such as systems with voltages up to 12V  and 20A. This type of controller is very reliable, there is no mechanical parts such as relays.


Tandem-type controller: the use of mechanical relays to control the charging process, and cut off the PV array at night. It is generally used for higher power systems, and the capacity of the relay determines the power level of the charge controller. It is easier to manufacture a series controller with a continuous energizing current of 45A or more.


Pulse Width Modulation Controller: It switches the input of the PV array in PWM pulse mode. When the battery tends to fill, the frequency and time of the pulse are shortened. According to the United States Sandia National Laboratory research, this charging process to form a more complete state of charge, it can increase the PV system in the battery's total cycle life.


Intelligent controller: the use of CPU with a single-chip (such as Intel's MCS51 series or Microchip PIC series) on the operating parameters of the photovoltaic power system for high-speed real-time acquisition, and in accordance with a certain control by the software program on the single or multiple The PV array is cut off / switched on. Medium, large-scale photovoltaic power supply system, but also through the microcontroller RS232 interface with MODEM modem for remote control.


The maximum power tracking controller: the solar battery voltage U and current I after detection multiplied by the power P, and then determine whether the sun battery output power at this time is the largest, if not at the maximum power point to run, adjust the pulse width, modulation Output duty cycle D, change the charging current, re-real-time sampling, and make changes to determine whether to change the duty cycle, through this optimization process to ensure that the solar cell is always running at the maximum power point to take full advantage of the output of solar cells energy. While the use of PWM modulation, so that the charge current into a pulse current to reduce the battery polarization, improve the charging efficiency.


JNDX series controller is designed according to the latest technology development,represents the latest photovoltaic technology level,and has many excellent performance. We can provide with you PV Solar Charge Controller,solar charge and discharge controller,wind solar hybrid controller,etc.


برچسب ها : ,,,
نویسنده:
تاریخ: شنبه 06 خرداد 1396
بازدید: 85

Recently, a news from Tianjin attracts people’s attention, “As the first enterprise who uses RFID technology in air-logistics, Sinotrans Air Transportation Development Co., Ltd. can handle over 200 orders per day with only 4 workers and 4 forklifts. With RFID readers installed on the forklift, workers can read the RFID tags on goods and complete the whole process quickly without getting off. The daily in&out cargo weight reaches 300 tons and the operation efficiency has been greatly improved than before.” The manager of this company also added that the work done within a week now just needs 24 hours.

RFID is the typical representative of automatic identification technology. It has many advantages of high accuracy, reliable performance, large capacity for information storage and oil/water resistant. RFID tags can do much better than traditional bar-code in the automated management of warehouse, to automated select, process and report the information of goods efficiently.

Shenzhe Clou IoT Technologies Co., Ltd. is the leading RFID devices&solutions provider. The RFID warehouse management solution provided by Clou can complete the simple batch process of in &out goods with self-owned long range UHF RFID reader, high-performance and special-type tag. Besides, it can make a clear record for the information of the sort, quantity, productive feature, stack position of goods so that workers can get good’s accurate data and supply chain information in every stage of logistics. By this way, enterprise can raise up the efficiency of putting goods to warehouse and realize the real-time management of products and goods allocation, also reduce the labor intensity and error probability for workers when goods out of warehouse.

نویسنده:
تاریخ: جمعه 05 خرداد 1396
بازدید: 121

1.Storage, packaging and transport services to ensure that the product zero defects in front of customers

Most people will pay attention to the system itself, this process is rarely focus on the system from the factory to the roof, small before have compared the brand manufacturers and a motley crew of packaging and transportation process, also found that this link there are too many fatal problems.


Many people may not know, storage conditions of household photovoltaic systems is very demanding requirements, must be stored in the constant temperature and humidity environment, humidity and temperature changes will cause the product power attenuation, affect the efficiency of power generation. In the course of transportation, a certain degree of vibration or excessive load will lead to the system battery components hidden crack.


Therefore, in addition to the original TRW household photovoltaic systems to do enough research in packaging materials and methods, but also on the transport routes of trial operation, select the best routes of transportation, packing, loading method and transportation vehicles, and transportation production manual, strict guidance of transport people to the control system in the implementation process, in the process of transportation quality.

 

2.Professional design and installation and construction services to ensure that the product is perfect in the roof Some time ago the Internet there are some domestic photovoltaic industry chaos, such as the roof of the Water Leakage problem is the installation of personnel is not professional, construction is not standardized, no waterproof treatment caused by the course, Xiao Bian also contacted more because of the design, installation and the problems caused by the loss, because of unreasonable design and installation angle, building block hot spot effect; because of the installation error caused the roof panels off; because of the design, installation error caused the roof collapse of whole cell components; even the line due to design problems directly lead to the fire, so that the team and the construction standard is really important professional design and installation.


But many businesses do not pay enough attention to this problem, because the manpower cost is too high, they disrupt the market with low price competition, cannot afford the expense, and they are holding out the trouble of mind, can make a fortune, even they themselves are not aware of the serious these questions, once a problem, they are ring.


Our company have strict process control in this link, the implementation of the price and set aside enough space to support this process, to ensure the safety of the whole construction process specification, the user does not have menace from the rear.

 

3.Customer tracking and maintenance of education services to ensure that the system can run stably for a long time. A lot of low-quality businesses or brand-name manufacturers in order to snatch customers resources, vicious price competition, disrupted the market price order, then reduce the quality of products, reduce personnel costs and maintenance costs to obtain their profits, resulting in a lot of rural people to install household photovoltaic power generation system, not only can not guarantee the power generation, power generation system also frequently failure, don't even say good maintenance management and PV knowledge training, thus also made many people install home photovoltaic system used for drying of radish and pepper jokes.

 

We to invest in a huge manpower, material and financial resources, build sales team in each of the provinces to help dealers to open up the market, organized the installer training school, on the installation of professional personnel can and knowledge training and awarded a certificate of graduation, held activities in Wan Zhen Photovoltaic Science National 1000 County. The spread of knowledge and knowledge of photovoltaic power generation products to more people.


We provide PV Solar Charge Controller,Wind Solar Hybrid Charge Controller,solar charge and discharge controller etc. Also,we provide whole solar power systems for household and commercial,solar street lighting system etc. as well.


برچسب ها : ,,,
نویسنده:
تاریخ: چهارشنبه 03 خرداد 1396
بازدید: 109

Greenpeace says China's waste of renewable energy is enough to power Beijing for a whole year Greenpeace, despite its commitment to correct the problem of waste renewable energy, is still rising sharply in the country's solar and wind power industries last year, Greenpeace said on Wednesday.


China is committed to improving the construction of transmission lines and renewable energy generation "rhythm" to avoid when there is not enough transmission lines to absorb renewable energy projects generated by the power of the scene when the phenomenon of abandoned electricity. But Greenpeace says China's wind rate has risen from 8% in 2014 to just over $17% last year, with Gansu's wind up as high as $43% last year. These wind power can not be integrated into the grid in 2015, the Chinese capital to power a year.

DC to AC pure sine wave inverter

2015 to 2016, China's solar power waste rate increased by 50%, of which Gansu and Xinjiang, more than 30% of solar energy is not incorporated into the grid. Greenpeace said Wednesday that the growing waste has reduced the industry's revenue by 34 billion 100 million yuan from 2015 to 2016.


In China, many areas only wind and solar power as the peak power supply backup power, leading to the latter after the decline in electricity consumption in idle state. With China's emphasis on building UHV transmission lines across the country, the construction of power grids (which produce renewable energy) has lagged behind. China needs to upgrade the grid. Data show that in the renewable energy base in Zhangjiakou, wind and solar power installed capacity has been more than 4 times the capacity of the local power grid.


Anhui JNGE POWER Co.,LTD is specialized in solar, wind  and other renewable energy power products.We are devoted to build our company as a greater contribution to society, and a well known  enterprise of new energy in the world.we provide Off Grid solar power system home,DC to AC pure sine wave inverter,Low frequency pure sine wave inverter etc.


برچسب ها : ,,,
نویسنده:
تاریخ: پنجشنبه 28 اردیبهشت 1396
بازدید: 129

PV modules capacity and inverter capacity ratio called capacity ratio. Reasonable capacity design need to be combined with the specific project situation. The main effective factors including irradiance, system loss, inverter efficiency, inverter life, inverter voltage range, modules installation angle and so on.


1. Different areas of different irradiance

Different regions have different solar illumination. Even in the same resource area, there is a big difference between different parts of the annual radiation


2. System loss

In PV system, the energy from the solar radiation to the PV module, through the DC cable, confluence box, DC power distribution to reach the inverter, which has lost all aspects of the link.The DC side loss is usually about 7-11%, the inverter loss of about 1-2%, the total loss of about 8-13%. The system loss does not include the inverter behind the transformer and Line loss part.

In other words, in the case where the capacity of the module and the inverter capacity are equal, the actual output maximum capacity of the inverter is only about 90% of the rated capacity of the inverter, even when the light is the best , The inverter is not fully loaded.


3. Inverter efficiency

The efficiency of the inverter is not constant value, there are power switching device loss and magnetic loss. The efficiency is relatively low if power is low. The highest efficiency is 40%-60%. The efficiency gradually reduced when over 60%.

Therefore, the total power of the PV power is controlled between 40% and 60%, the inverter power to achieve optimum efficiency.


4. The lifetime of the inverter

PV inverter is an electronic product. It has a great relationship with reliability and inverter operating temperature. If capacitors, fans, relays and other components temperature increased by 10 ℃, the failure rate can be increased by more than 50%. While the operating temperature is related to power.

According to statistics, the lifetime of inverter long-term work in the power 80-100% lower than40-60%.


5. The optimum operating voltage range of the inverter

The operating voltage is rated at the highest rated operating voltage of the inverter.

Single phase 220V inverter, the input rated voltage is 360V, three phase 380V inverter, the input rated voltage is 650V.


260W solar panel modules, operating voltage is 30.5V, if equipped with 3kW inverter, using 12 working voltage 366V, it is best that 3.12KW total power.


If equipped with 30kW inverter, 126sets solar panel modules, each 21 string, the voltage is 640.5V, it is best that 32.76KW total power.


Anhui JNGE POWER Co.,LTD as a professional DC to AC pure sine wave inverter manufacturer in China,can provide you high frequency inverter,Low frequency pure sine wave inverter and other products.


برچسب ها : ,,,

ليست صفحات

تعداد صفحات : 25